• Register
  • Log in
  • Wishlist (0)
Safety Unlimited Store
Close
  • Gas Detection
    • Back
    • RKI Instruments
      • Back
      • Single Gas Monitors
        • Back
        • 03 Series for O2/LEL/CO/H2S
          • Back
          • OX-03 for O2
          • GP-03 for LEL w/Alkaline Batteries
          • GP-03 for LEL w/NiHM Batteries
          • CO-03 for CO
          • HS-03 for H2S
        • SC-01 Toxic Gas Monitor
        • OX-07 Oxygen Monitor
      • Multi-Gas Monitors
        • Back
        • EAGLE 2 Portable Series
        • EAGLE Portable Series
        • GX-6000 Series
        • GX-2012 Series
        • GX-2009 SERIES
        • Gas Tracer
      • Specialty Monitors
      • Calibration Equipment
        • Back
        • Calibration Stations
        • Calibration Kits
          • Back
          • For Single Gas 03 Series
        • Calibration Gases
    • Parts & Accessories
      • Back
      • Battery Chargers and Enclosures
        • Back
        • for RKI Instruments
          • Back
          • Eagle 2 Battery Options
      • Replacement Sensors
  • Training CDs/DVDs
    Training on CD-ROM
    Picture for category Training on CD-ROM
    • Initial Training
    • Refresher Training
  • Automatic External Defibrillators (AED)
    DefibTech Automatic External Defibrillators (AED)
    Picture for category DefibTech Automatic External Defibrillators (AED)
    Philips Automatic External Defibrillators (AED)
    Picture for category Philips Automatic External Defibrillators (AED)
    Physio Control Automatic External Defibrillator (AED)
    Picture for category Physio Control Automatic External Defibrillator (AED)
    HeartSine Automatic External Defibrillator (AED)
    Picture for category HeartSine Automatic External Defibrillator (AED)
    Cardiac Science Automatic External Defibrillators (AED)
    Picture for category Cardiac Science Automatic External Defibrillators (AED)
Menu
  • Gas Detection
    • Back
    • RKI Instruments
      • Back
      • Single Gas Monitors
        • Back
        • 03 Series for O2/LEL/CO/H2S
          • Back
          • OX-03 for O2
          • GP-03 for LEL w/Alkaline Batteries
          • GP-03 for LEL w/NiHM Batteries
          • CO-03 for CO
          • HS-03 for H2S
        • SC-01 Toxic Gas Monitor
        • OX-07 Oxygen Monitor
      • Multi-Gas Monitors
        • Back
        • EAGLE 2 Portable Series
        • EAGLE Portable Series
        • GX-6000 Series
        • GX-2012 Series
        • GX-2009 SERIES
        • Gas Tracer
      • Specialty Monitors
      • Calibration Equipment
        • Back
        • Calibration Stations
        • Calibration Kits
          • Back
          • For Single Gas 03 Series
        • Calibration Gases
    • Parts & Accessories
      • Back
      • Battery Chargers and Enclosures
        • Back
        • for RKI Instruments
          • Back
          • Eagle 2 Battery Options
      • Replacement Sensors
  • Training CDs/DVDs
    • Back
    • Training on CD-ROM
      • Back
      • Initial Training
      • Refresher Training
  • Automatic External Defibrillators (AED)
    • Back
    • DefibTech Automatic External Defibrillators (AED)
    • Philips Automatic External Defibrillators (AED)
    • Physio Control Automatic External Defibrillator (AED)
    • HeartSine Automatic External Defibrillator (AED)
    • Cardiac Science Automatic External Defibrillators (AED)
  • Home
  • eLearning Website
  • Contact Us
Menu
  • Home
  • eLearning Website
  • Contact Us
(0) items
You have no items in your shopping cart.
All Categories
    Menu
    Shopping cart
    Filters
    Personal menu
    Preferences
    Search
    • Home /
    • Automatic External Defibrillators (AED) /
    • Philips Automatic External Defibrillators (AED) /
    • Heartstart OnSite AED (Home)
    PrevHeartStart FRx AED
    NextHeartStart FRx AED
    Picture of Heartstart OnSite AED (Home)

    Heartstart OnSite AED (Home)

    Be the first to review this product
    $1,354.00
    Designed for the ordinary person in the extraordinary moment, Philips HeartStart OnSite AED is ready to act and virtually ready to go. It allows anyone with little or no training to treat the most common cause of suspected sudden cardiac arrest (SCA) by delivering a shock quickly and effectively, wherever SCA happens. The OnSite AED provides practically real-time guidance through step-by-step voice commands from pad placement to performing CPR. When every minute counts, Philips HeartStart OnSite AED is the partner by your side. Side by side. Step by step.
    • Overview
    • Reviews
    • Contact Us

    Specifications

    Battery
    Type
    • 9 volt DC, 4.2 Ah, composed of disposable long-life lithium manganese dioxide primary cells
    Capacity
    • Minimum 200 shocks or 4 hours of operating time (EN60601-2-4:2003)
    Install-by Date
    • Battery is labeled with an install-by date of at least five years from date of manufacture
    Standby Life
    • Four years typical when battery is installed by the install-by date. (Will power the AED in standby state within the specified Standby Temperature range, assuming one battery insertion test and no defibrillation uses)
    Product Specifications
    Kit Contents
    • Defibrillator, battery (one, pre-installed), SMART Pads (one set, pre-installed), set-up/maintenance guide with expiration date tags, owner's manual, quick reference guide
    Waveform
    • SMART Truncated exponential biphasic. Waveform parameters adjusted as a function of patient impedance
    Defibrillation peak current - Adult
    • 32 A (150 J nominal) into a 50 ohm load
    Defibrillation peak current - Pediatric
    • 19 A (50 J nominal) into a 50 ohm load (using optional infant/child SMART Pads Cartridge)
    Shock-to-Shock Cycle Time
    • Typically less than 20 seconds between shocks in a series
    Quick Shock
    • Able to deliver a shock after the end of a CPR interval, typically in eight seconds
    Voice Instructions
    • Detailed voice messages guide responder through use of the defibrillator
    CPR Guidance
    • Instructions for adult and infant/child CPR available at user selection
    Shock Delivery
    • Via adhesive pads placed on patient's bare skin as illustrated on pads
    Controls
    • Green SMART Pads cartridge handle, green On/Off button, blue i-button, orange Shock button
    Indicators
    • Ready light, blue i-button, caution light
    Environmental/Physical Requirements
    Standby Temperature
    • 0 - 43 °C (32 - 109 °F)
    Operating Humidity
    • 0 to 95 % relative humidity (non-condensing)
    Standby Humidity
    • 0 to 75 % relative humidity (non-condensing)
    Standby Altitude
    • > 48 hours from 0 to 8,500 ft and <48 hours from 8,500 to 15,000 ft
    EMI (Radiated/Immunity)
    • Meets EN55011 Group 1 Level B Class B and EN61000-4-3
    SMART Pads
    Energy delivered
    • Adult: nominal 150 joules into a 50 ohm load; Infant/Child: nominal 50 joules into a 50 ohm load
    How Supplied
    • Disposable cartridge, containing adhesive defibrillation pads, clicks into defibrillator for an integrated pads solution
    Active Surface Area
    • 85 cm² (13.2 in²) each
    Cable Length
    • Adult pads: 137 cm (54"); Infant/Child pads: 102 cm (40")
    Use-by Date
    • Cartridge is labeled with a use-by date of at least two years from date of manufacture
    Training pads (optional)
    • Special pads put HeartStart OnSite into training mode and disable its energy delivery capability. Training pads feature 8 real-world training scripts. Use with training mat (included) or with adapters on manikins
    Environmental/Physical Requirements
    Sealing
    • Solid objects per EN60529 class IP2X; Drip-proof per EN60529 class IPX1
    Operating Temperature
    • 0 - 50 °C (32 - 122 °F)
    Operating Altitude
    • 0 to 4,500 m (0 to 15,000 ft)
    Shock/Drop Abuse Tolerance
    • Withstands 1 meter drop to any edge, corner, or surface
    Vibration
    • Meets EN1789 random and swept sine, road ambulance specification in operating and standby states
    Automated and User-activated Self-tests
    Daily Automatic Self-tests
    • Tests internal circuitry, waveform delivery system, pads cartridge, and battery capacity
    Pads Integrity Test
    • Specifically tests readiness-for-use of pads (gel moisture)
    Battery Insertion Test
    • Upon battery insertion, extensive automatic self-tests and user-interactive tests check device readiness
    Status Indicator
    • Blinking green "Ready" light indicates ready for use. Audible "chirp" indicates need for maintenance
    Data Recording and Transmission
    Infrared
    • Wireless transmission of event data to a PC or Palm PDA, using the IrDA protocol
    Data Stored
    • First 15 minutes of ECG and the entire incident's events and analysis decisions
    Write your own review
    • Product can be reviewed only after purchasing it
    • Only registered users can write reviews
    • Bad
    • Excellent

    Specifications

    Battery
    Type
    • 9 volt DC, 4.2 Ah, composed of disposable long-life lithium manganese dioxide primary cells
    Capacity
    • Minimum 200 shocks or 4 hours of operating time (EN60601-2-4:2003)
    Install-by Date
    • Battery is labeled with an install-by date of at least five years from date of manufacture
    Standby Life
    • Four years typical when battery is installed by the install-by date. (Will power the AED in standby state within the specified Standby Temperature range, assuming one battery insertion test and no defibrillation uses)
    Product Specifications
    Kit Contents
    • Defibrillator, battery (one, pre-installed), SMART Pads (one set, pre-installed), set-up/maintenance guide with expiration date tags, owner's manual, quick reference guide
    Waveform
    • SMART Truncated exponential biphasic. Waveform parameters adjusted as a function of patient impedance
    Defibrillation peak current - Adult
    • 32 A (150 J nominal) into a 50 ohm load
    Defibrillation peak current - Pediatric
    • 19 A (50 J nominal) into a 50 ohm load (using optional infant/child SMART Pads Cartridge)
    Shock-to-Shock Cycle Time
    • Typically less than 20 seconds between shocks in a series
    Quick Shock
    • Able to deliver a shock after the end of a CPR interval, typically in eight seconds
    Voice Instructions
    • Detailed voice messages guide responder through use of the defibrillator
    CPR Guidance
    • Instructions for adult and infant/child CPR available at user selection
    Shock Delivery
    • Via adhesive pads placed on patient's bare skin as illustrated on pads
    Controls
    • Green SMART Pads cartridge handle, green On/Off button, blue i-button, orange Shock button
    Indicators
    • Ready light, blue i-button, caution light
    Environmental/Physical Requirements
    Standby Temperature
    • 0 - 43 °C (32 - 109 °F)
    Operating Humidity
    • 0 to 95 % relative humidity (non-condensing)
    Standby Humidity
    • 0 to 75 % relative humidity (non-condensing)
    Standby Altitude
    • > 48 hours from 0 to 8,500 ft and <48 hours from 8,500 to 15,000 ft
    EMI (Radiated/Immunity)
    • Meets EN55011 Group 1 Level B Class B and EN61000-4-3
    SMART Pads
    Energy delivered
    • Adult: nominal 150 joules into a 50 ohm load; Infant/Child: nominal 50 joules into a 50 ohm load
    How Supplied
    • Disposable cartridge, containing adhesive defibrillation pads, clicks into defibrillator for an integrated pads solution
    Active Surface Area
    • 85 cm² (13.2 in²) each
    Cable Length
    • Adult pads: 137 cm (54"); Infant/Child pads: 102 cm (40")
    Use-by Date
    • Cartridge is labeled with a use-by date of at least two years from date of manufacture
    Training pads (optional)
    • Special pads put HeartStart OnSite into training mode and disable its energy delivery capability. Training pads feature 8 real-world training scripts. Use with training mat (included) or with adapters on manikins
    Environmental/Physical Requirements
    Sealing
    • Solid objects per EN60529 class IP2X; Drip-proof per EN60529 class IPX1
    Operating Temperature
    • 0 - 50 °C (32 - 122 °F)
    Operating Altitude
    • 0 to 4,500 m (0 to 15,000 ft)
    Shock/Drop Abuse Tolerance
    • Withstands 1 meter drop to any edge, corner, or surface
    Vibration
    • Meets EN1789 random and swept sine, road ambulance specification in operating and standby states
    Automated and User-activated Self-tests
    Daily Automatic Self-tests
    • Tests internal circuitry, waveform delivery system, pads cartridge, and battery capacity
    Pads Integrity Test
    • Specifically tests readiness-for-use of pads (gel moisture)
    Battery Insertion Test
    • Upon battery insertion, extensive automatic self-tests and user-interactive tests check device readiness
    Status Indicator
    • Blinking green "Ready" light indicates ready for use. Audible "chirp" indicates need for maintenance
    Data Recording and Transmission
    Infrared
    • Wireless transmission of event data to a PC or Palm PDA, using the IrDA protocol
    Data Stored
    • First 15 minutes of ECG and the entire incident's events and analysis decisions
    Information
    • Contact Us
    • About Safety Unlimited
    • Terms & Conditions
    • Privacy Policy
    Customer service
    My account
    • Customer info
    • Addresses
    • Orders
    • Shopping cart
    • Wishlist
    • Compare products list
    • Apply for vendor account
    Contact Us
    • 2139 Tapo Street Ste.228 Simi Valley, CA 93063
    • info@safetyunlimited.com
    • (888) 309-SAFE (7233)
    Copyright © 2021 Safety Unlimited Store. All rights reserved.